DIRECT DRIVE VALVES, PROPORTIONAL VALVES & SERVOVALVES
FACT can provide you develop tests mean in order to perform your tests :
Performance of our tests benchs/means are as follow :
1. Fuel test bench (1 inlet and3 outlets)
Hydraulic power :
-
1600L/H@70 bar pump (JET A or MIL PRF 23699) ATEX.
-
Cooling circuit
Measuring, data acquisition and control:
-
3 Coriolis effect flowmeters (1 on an inlet et 2 on an equipment outlets)
-
±0,1% of mesured value
-
-
3 Pressure sensors
-
±0,1% of full scale
-
-
Autonomous endurance test possible
-
Control and datas acquisition with Labview equipment
2. Air test bench air (1 inlet and 1 outlet)
Pneumatic Power :
-
50g/s @2.5 bar air Compressor 50g ( Ambiant air).
-
Air heater up to 250°C
-
Measuring, data acquisition and control:
-
1 Coriolis effect flowmeter
-
±0,1% of mesured value
-
-
3 Pressure sensors
-
±0,1% of full scale
-
-
Autonomous endurance test possible
-
Control and datas acquisition with Gantnerr Instrument
-
3. Oil test bench (1 inlet and3outlets)
Hydraulic power :
-
15000l/H @70 bar pump (MIL-PRF-23699).
-
Pompe 15000l/h@ 70 bar (MIL-PRF-23699).
-
Oil heater 160°C
-
Oil Cooling up to -42°C
Measuring, data acquisition and control:
-
3 Coriolis effect flowmeters (1 on an inlet et 2 on an equipment outletS) ±0,1% of mesured value
-
7 Pressure sensors 1.±0,1% of full scale
-
Autonomous endurance test possible
-
Control and datas acquisition with Gantnerr Instrument
4. Climatic chamber for operating and not operating equipment test
-
Temperature controlled [ -72°C; +180°C ]
-
Heat variation 4°C/min
-
Cooling variation 3°C/min
-
180 liters tests volumes (550mm Large, 740mm Heigh, 420mm depth)
5. Azote test bench
-
1 azote compressed bottle
-
A set of 3 valves and 2L tank set in order to mesure equipment leakage.
6. Oil and fuel pollution tests bench
-
1200l/h@ 280 bar pump (Fluid JET A1)
-
Precise setting of outlet pump pressure
-
Oil heating up to 140°C
-
Polluant injecting up Ø1mm
-
Easily movable
7. Dilectric and milliohmeter
-
Breakdownvoltage
• Measuring range : [0.01mA – 10mA] for 5kV AC or 6kV DC max supply
-
Insulation between active and not-active material
• Measuring range: [50kW – 200GW] for 10V to 500V DC max supply
-
Mass resistance measurement between the different exterior not-active part of the equipement
• Measuring range: [1mW - 6kW] for 1mA to 5A supply